Overview
Global Energy Monitor tracks 2 units or phases at this site (operating 1.77 GW).
Technology: supercritical; fuel: coal: bituminous.
Ownership: Prairie Power Inc; Wabash Valley Power Association Inc; Missouri Joint Municipal Electric Utility Commission; Southern Illinois Power Cooperative Inc; Indiana Municipal Power Agency; Kentucky Municipal Power Agency… (parent company: small shareholder(s); Illinois Municipal Elec Agency; Indiana Municipal Power Agency; Missouri Joint Municipal Electric Utility Commission; Prairie Power Inc…).
Why it matters
- Provides about 1.1% of United States's operating coal capacity.
- At a typical capacity factor of 50% for this technology, it would generate roughly 7.7 TWh of electricity a year (indicative estimate).
Coal-fired units are typically run as baseload or mid-merit plants and are the most carbon-intensive form of power generation, which makes their retirement schedules a key indicator of national transition plans.
Coal power in United States
United States has 167.4 GW of operating coal capacity across 181 plants in the Global Energy Monitor dataset — 13% of the country's total operating power capacity of 1,280.9 GW.
The coal pipeline in United States includes 6.24 GW under construction and 6.81 GW at earlier planning stages.
Other major coal plants in United States include Homer City Generating Station (4.71 GW), Parish Generating Station (3.95 GW) and Plant Bowen (3.50 GW).
Units and phases
| Unit / phase | Capacity | Status | Technology | Start | Retired |
|---|---|---|---|---|---|
| Unit 1 | 883 MW | supercritical | 2012 | ||
| Unit 2 | 883 MW | supercritical | 2012 |
How coal power plants work
A coal-fired power station burns pulverised coal in a boiler to turn water into high-pressure steam, which spins a turbine connected to a generator. After passing through the turbine the steam is condensed back into water — usually with river, sea or cooling-tower water — and pumped back to the boiler.
Efficiency depends mainly on steam temperature and pressure: older subcritical units convert roughly a third of the coal's energy into electricity, while modern supercritical and ultra-supercritical units reach 40–47%. Each megawatt-hour from coal emits roughly 0.8–1.1 tonnes of CO₂, the highest of any major power source, which is why many countries have set coal phase-out dates.
Technology at Prairie State Energy Campus
Supercritical units operate above the critical pressure of water, reaching efficiencies of roughly 38–42% and lower emissions per megawatt-hour than subcritical units.
Location
Prairie State Energy Campus is located in Illinois, United States, at approximately 38.2783, -89.6686. Open the interactive map to explore nearby power plants, high-voltage lines and substations.
Ownership
Prairie State Energy Campus is owned by Prairie Power Inc; Wabash Valley Power Association Inc; Missouri Joint Municipal Electric Utility Commission; Southern Illinois Power Cooperative Inc; Indiana Municipal Power Agency; Kentucky Municipal Power Agency; Northern Illinois Municipal Power Agency…. The ultimate parent company is small shareholder(s); Illinois Municipal Elec Agency; Indiana Municipal Power Agency; Missouri Joint Municipal Electric Utility Commission; Prairie Power Inc; Kentucky Municipal Power Agency…. Across the dataset, small shareholder(s) is linked to 404 power plants in 66 countries, with 111.3 GW of operating capacity.
Frequently asked questions
What is the capacity of Prairie State Energy Campus?
Prairie State Energy Campus has a capacity of 1.77 GW according to the latest Global Energy Monitor data. This figure covers the 2 units or phases listed for the site.
What type of facility is Prairie State Energy Campus?
Prairie State Energy Campus is a coal-fired power station. Supercritical units operate above the critical pressure of water, reaching efficiencies of roughly 38–42% and lower emissions per megawatt-hour than subcritical units.
Who owns Prairie State Energy Campus?
Prairie State Energy Campus is owned by Prairie Power Inc; Wabash Valley Power Association Inc; Missouri Joint Municipal Electric Utility Commission; Southern Illinois Power Cooperative Inc; Indiana Municipal Power Agency; Kentucky Municipal Power Agency; Northern Illinois Municipal Power Agency; Illinois Municipal Elec Agency; American…. The ultimate parent company is small shareholder(s); Illinois Municipal Elec Agency; Indiana Municipal Power Agency; Missouri Joint Municipal Electric Utility Commission; Prairie Power Inc; Kentucky Municipal Power Agency….
Where is Prairie State Energy Campus located?
It is located in Illinois, United States. Approximate coordinates: 38.2783, -89.6686.
Is Prairie State Energy Campus operational?
According to the latest data, Prairie State Energy Campus is in operation. Operating means the facility is built and in commercial service.
When did Prairie State Energy Campus start operating?
Start year: 2012. Current status: Operating.
How much electricity does Prairie State Energy Campus generate?
Actual output data are not published for every plant. As an indicative estimate, Prairie State Energy Campus would produce about 7.7 TWh a year, assuming a capacity factor of 50%, which is typical for this technology.
How big is Prairie State Energy Campus compared with other facilities in United States?
Prairie State Energy Campus ranks #28 by capacity among 181 comparable coal facilities tracked in United States.