Overview
Global Energy Monitor tracks 8 units or phases at this site (operating 3.24 GW, retired 1.08 GW).
Technology: pressurized heavy water reactor.
Ownership: Ontario Power Generation Inc.
Its 6 operating units were commissioned between 1971 and 1986. 2 units have already been retired (2007–2008).
Why it matters
- The 3rd-largest nuclear power plant in Canada by capacity (of 4 operating nuclear facilities tracked).
- Provides about 22% of Canada's operating nuclear capacity and roughly 2.1% of all operating power capacity in the country in the dataset.
- Ranks #38 worldwide among nuclear facilities of the same status group by capacity.
- At a typical capacity factor of 85% for this technology, it would generate roughly 24 TWh of electricity a year (indicative estimate).
Nuclear plants supply large volumes of low-carbon baseload electricity with very high capacity factors, so a single station can cover a significant share of national demand.
Nuclear power in Canada
Canada has 14.6 GW of operating nuclear capacity across 4 plants in the Global Energy Monitor dataset — 9.6% of the country's total operating power capacity of 152.6 GW.
The nuclear pipeline in Canada includes 1.20 GW under construction and 15.7 GW at earlier planning stages.
Other major nuclear plants in Canada include Bruce nuclear power plant (6.94 GW), Darlington nuclear power plant (3.74 GW) and Darlington New nuclear power plant (1.20 GW).
Units and phases
| Unit / phase | Capacity | Status | Technology | Start | Retired |
|---|---|---|---|---|---|
| A1 | 542 MW | pressurized heavy water reactor | 1971 | ||
| A2 | 542 MW | Retired | pressurized heavy water reactor | 1971 | 2007 |
| A3 | 542 MW | Retired | pressurized heavy water reactor | 1972 | 2008 |
| A4 | 542 MW | pressurized heavy water reactor | 1973 | ||
| B5 | 540 MW | pressurized heavy water reactor | 1983 | ||
| B6 | 540 MW | pressurized heavy water reactor | 1984 | ||
| B7 | 540 MW | pressurized heavy water reactor | 1985 | ||
| B8 | 540 MW | pressurized heavy water reactor | 1986 |
How nuclear power plants work
A nuclear power plant uses heat from controlled fission of uranium (or plutonium) fuel in a reactor core to produce steam, which drives a turbine-generator in the same way as a thermal power station. The reactor is surrounded by multiple safety barriers and a containment building.
Nuclear units typically run more than 90% of the hours in a year, so a single large reactor can supply several terawatt-hours of almost carbon-free electricity annually. Construction times are long and capital costs high, but fuel costs are low and plants are often licensed to operate for 60 years or more.
Technology at Pickering nuclear power plant
Pressurised heavy water reactors (PHWR), such as the CANDU design, use heavy water as moderator and coolant and can run on natural uranium.
Location
Pickering nuclear power plant is located in Ontario, Canada, at approximately 43.8107, -79.0689. Open the interactive map to explore nearby power plants, high-voltage lines and substations.
Ownership
Pickering nuclear power plant is owned by Ontario Power Generation Inc. Across the dataset, Ontario Power Generation Inc is linked to 49 power plants with 26.3 GW of operating capacity.
Frequently asked questions
What is the capacity of Pickering nuclear power plant?
Pickering nuclear power plant has a capacity of 3.24 GW according to the latest Global Energy Monitor data. This figure covers the 8 units or phases listed for the site.
What type of facility is Pickering nuclear power plant?
Pickering nuclear power plant is a nuclear power plant. Pressurised heavy water reactors (PHWR), such as the CANDU design, use heavy water as moderator and coolant and can run on natural uranium.
Who owns Pickering nuclear power plant?
Pickering nuclear power plant is owned by Ontario Power Generation Inc.
Where is Pickering nuclear power plant located?
It is located in Ontario, Canada. Approximate coordinates: 43.8107, -79.0689.
Is Pickering nuclear power plant operational?
According to the latest data, Pickering nuclear power plant is in operation. Operating means the facility is built and in commercial service.
When did Pickering nuclear power plant start operating?
Start year: 1971. Current status: Operating. Its 6 operating units were commissioned between 1971 and 1986. 2 units have already been retired (2007–2008).
How much electricity does Pickering nuclear power plant generate?
Actual output data are not published for every plant. As an indicative estimate, Pickering nuclear power plant would produce about 24 TWh a year, assuming a capacity factor of 85%, which is typical for this technology.
How big is Pickering nuclear power plant compared with other facilities in Canada?
Pickering nuclear power plant ranks #3 by capacity among 4 comparable nuclear facilities tracked in Canada.
Latest news on Pickering nuclear power plant
OPG, Aecon Sign C$3 Billion Contracts to Begin Pickering Nuclear Refurbishment
BWXT Completes $56M Expansion of Its Cambridge Nuclear Plant
OPG Says Canada’s First Small Modular Reactor Will Miss 2030 Target, Launches Cost Review
Indiana Weighs Up to 6 GW of Canadian Candu Reactors Under New AtkinsRéalis MoU
Bruce Power’s Unit 4 Refurbishment Beats Schedule as Calandria Tube Installation Wraps Up