Overview
Global Energy Monitor tracks 12 units or phases at this site (operating 1.68 GW, planned 850 MW, shelved / mothballed 2.25 GW).
Technology: steam turbine, combined cycle; fuel: natural gas, fossil liquids: fuel oil, fossil liquids: diesel, unknown.
Ownership: Dalia Energy Companies Ltd (parent company: Meshek Energy - Renewable Energies Ltd; Hiram-Epsilon Ltd; Daniel Caesarea Holdings; Orot Energy Holdings LP).
Its 6 operating units were commissioned between 1974 and 2014. 1 further units or phases are scheduled to come online in 2029. 4 operating units have a planned retirement date, the earliest in 2026.
Why it matters
- The 2nd-largest oil- and gas-fired power station in Israel by capacity (of 28 operating oil & gas facilities tracked).
- Provides about 10% of Israel's operating oil & gas capacity and roughly 8.3% of all operating power capacity in the country in the dataset.
- At a typical capacity factor of 40% for this technology, it would generate roughly 5.9 TWh of electricity a year (indicative estimate).
Gas-fired plants — especially combined-cycle units — provide flexible output that can ramp quickly to balance demand and variable renewables, so their availability is closely tied to gas supply and prices.
Oil & gas power in Israel
Israel has 16.7 GW of operating oil & gas capacity across 28 plants in the Global Energy Monitor dataset — 82% of the country's total operating power capacity of 20.4 GW.
The oil & gas pipeline in Israel includes 3.70 GW under construction and 2.40 GW at earlier planning stages.
Other major oil & gas plants in Israel include Orot Rabin power station (3.91 GW), Hagit power station (1.40 GW) and Sorek PPP power station (1.40 GW).
Units and phases
| Unit / phase | Capacity | Status | Technology | Start | Retired |
|---|---|---|---|---|---|
| A | 228 MW | steam turbine | 1974 | 2026 | |
| Avshal power plant | 850 MW | Pre-construction | combined cycle | 2029 | |
| B | 228 MW | steam turbine | 1975 | 2026 | |
| C | 228 MW | steam turbine | 1978 | 2026 | |
| CC | 450 MW | Shelved | combined cycle | ||
| CC -Replacement of unit D | 450 MW | Shelved | combined cycle | ||
| CC- Replacement of unit C | 450 MW | Shelved | combined cycle | ||
| CC-Replacement of unit A | 450 MW | Shelved | combined cycle | ||
| CC-Replacement of unit B | 450 MW | Shelved | combined cycle | ||
| CC1 | 377 MW | combined cycle | 2005 | ||
| CC2 | 394 MW | combined cycle | 2014 | ||
| D | 228 MW | steam turbine | 1977 | 2026 |
How gas & oil power plants work
Gas- and oil-fired power plants burn fuel either in a gas turbine, a steam boiler or a reciprocating engine. In a combined-cycle plant the hot exhaust of the gas turbine is used to raise steam for a second, steam-driven turbine, lifting overall efficiency to 55–62%.
Because gas units can start quickly and change output within minutes, they play a central role in balancing electricity systems with growing shares of wind and solar. Their operating costs track fuel prices closely, so gas supply security — via pipelines or LNG — directly affects how often they run. A modern combined-cycle plant emits roughly 0.35–0.4 tonnes of CO₂ per megawatt-hour.
Technology at Eshkol power station
Combined-cycle units pair gas turbines with a heat-recovery steam generator and steam turbine, reaching efficiencies of 55–62% — the highest of any thermal power plant. Steam-turbine units burn fuel in a boiler to raise steam; they are generally older and less flexible than combined-cycle plants.
Location
Eshkol power station is located in HaDarom, Israel, at approximately 31.8388, 34.6551. Open the interactive map to explore nearby power plants, high-voltage lines and substations.
Ownership
Eshkol power station is owned by Dalia Energy Companies Ltd. The ultimate parent company is Meshek Energy - Renewable Energies Ltd; Hiram-Epsilon Ltd; Daniel Caesarea Holdings; Orot Energy Holdings LP. Across the dataset, Meshek Energy - Renewable Energies Ltd is linked to 3 power plants with 2.58 GW of operating capacity.
Frequently asked questions
What is the capacity of Eshkol power station?
Eshkol power station has a capacity of 1.68 GW according to the latest Global Energy Monitor data. This figure covers the 12 units or phases listed for the site.
What type of facility is Eshkol power station?
Eshkol power station is a oil- and gas-fired power station. Combined-cycle units pair gas turbines with a heat-recovery steam generator and steam turbine, reaching efficiencies of 55–62% — the highest of any thermal power plant.
Who owns Eshkol power station?
Eshkol power station is owned by Dalia Energy Companies Ltd. The ultimate parent company is Meshek Energy - Renewable Energies Ltd; Hiram-Epsilon Ltd; Daniel Caesarea Holdings; Orot Energy Holdings LP.
Where is Eshkol power station located?
It is located in HaDarom, Israel. Approximate coordinates: 31.8388, 34.6551.
Is Eshkol power station operational?
According to the latest data, Eshkol power station is in operation. Operating means the facility is built and in commercial service.
When did Eshkol power station start operating?
Start year: 1974. Current status: Operating. Its 6 operating units were commissioned between 1974 and 2014. 1 further units or phases are scheduled to come online in 2029. 4 operating units have a planned retirement date, the earliest in 2026.
How much electricity does Eshkol power station generate?
Actual output data are not published for every plant. As an indicative estimate, Eshkol power station would produce about 5.9 TWh a year, assuming a capacity factor of 40%, which is typical for this technology.
How big is Eshkol power station compared with other facilities in Israel?
Eshkol power station ranks #2 by capacity among 28 comparable oil & gas facilities tracked in Israel.