Coal · United States

Sooner Generating Station

Sooner Generating Station is a 1.14 GW coal-fired power station located in Oklahoma, United States. The facility is currently in operation, with its first unit entering service in 1979.

1.14 GWCapacity
OperatingStatus
1979Start year
View on the interactive map →

Overview

Global Energy Monitor tracks 2 units or phases at this site (operating 1.14 GW).

Technology: subcritical; fuel: coal: subbituminous.

Ownership: Oklahoma Gas and Electric Co (parent company: OGE Energy Corp).

Its 2 operating units were commissioned between 1979 and 1980.

Why it matters

  • At a typical capacity factor of 50% for this technology, it would generate roughly 5.0 TWh of electricity a year (indicative estimate).

Coal-fired units are typically run as baseload or mid-merit plants and are the most carbon-intensive form of power generation, which makes their retirement schedules a key indicator of national transition plans.

Coal power in United States

United States has 167.4 GW of operating coal capacity across 181 plants in the Global Energy Monitor dataset — 13% of the country's total operating power capacity of 1,280.9 GW.

The coal pipeline in United States includes 6.24 GW under construction and 6.81 GW at earlier planning stages.

Other major coal plants in United States include Homer City Generating Station (4.71 GW), Parish Generating Station (3.95 GW) and Plant Bowen (3.50 GW).

See the full list: Coal power plants in United States →

Units and phases

Unit / phaseCapacityStatusTechnologyStartRetired
Unit 1 569 MW Operating subcritical 1979
Unit 2 569 MW Operating subcritical 1980

How coal power plants work

A coal-fired power station burns pulverised coal in a boiler to turn water into high-pressure steam, which spins a turbine connected to a generator. After passing through the turbine the steam is condensed back into water — usually with river, sea or cooling-tower water — and pumped back to the boiler.

Efficiency depends mainly on steam temperature and pressure: older subcritical units convert roughly a third of the coal's energy into electricity, while modern supercritical and ultra-supercritical units reach 40–47%. Each megawatt-hour from coal emits roughly 0.8–1.1 tonnes of CO₂, the highest of any major power source, which is why many countries have set coal phase-out dates.

Technology at Sooner Generating Station

Subcritical units are the oldest and least efficient coal-plant design, typically converting about 33–37% of the fuel's energy into electricity.

Location

Imagery © Esri, Maxar, Earthstar Geographics

Sooner Generating Station is located in Oklahoma, United States, at approximately 36.4545, -97.0524. Open the interactive map to explore nearby power plants, high-voltage lines and substations.

Ownership

Sooner Generating Station is owned by Oklahoma Gas and Electric Co. The ultimate parent company is OGE Energy Corp. Across the dataset, OGE Energy Corp is linked to 9 power plants with 8.21 GW of operating capacity.

Frequently asked questions

What is the capacity of Sooner Generating Station?

Sooner Generating Station has a capacity of 1.14 GW according to the latest Global Energy Monitor data. This figure covers the 2 units or phases listed for the site.

What type of facility is Sooner Generating Station?

Sooner Generating Station is a coal-fired power station. Subcritical units are the oldest and least efficient coal-plant design, typically converting about 33–37% of the fuel's energy into electricity.

Who owns Sooner Generating Station?

Sooner Generating Station is owned by Oklahoma Gas and Electric Co. The ultimate parent company is OGE Energy Corp.

Where is Sooner Generating Station located?

It is located in Oklahoma, United States. Approximate coordinates: 36.4545, -97.0524.

Is Sooner Generating Station operational?

According to the latest data, Sooner Generating Station is in operation. Operating means the facility is built and in commercial service.

When did Sooner Generating Station start operating?

Start year: 1979. Current status: Operating. Its 2 operating units were commissioned between 1979 and 1980.

How much electricity does Sooner Generating Station generate?

Actual output data are not published for every plant. As an indicative estimate, Sooner Generating Station would produce about 5.0 TWh a year, assuming a capacity factor of 50%, which is typical for this technology.

How big is Sooner Generating Station compared with other facilities in United States?

Sooner Generating Station ranks #63 by capacity among 181 comparable coal facilities tracked in United States.

Nearby energy infrastructure

Other assets of the same owner

Sources and methodology

Source: Global Energy Monitor, Global Integrated Power Tracker, 2026-09 release. Full project profile on GEM.wiki. Last updated: 8 October 2026.

Capacity, status, ownership and unit details come from Global Energy Monitor's public trackers, which are compiled from company reports, government filings and news coverage and updated several times a year. Rankings and shares are calculated by The Daily Energy from the same dataset. Estimated annual generation uses typical capacity factors for each technology and is indicative only.

Data: Global Energy Monitor (GIPT 2026-09, GGIT 2025-11, GOIT 2026-06, GOGET 2026-03, GCMT 2026-08, OSM 2026-10) licensed under CC BY 4.0; transmission grid © OpenStreetMap contributors (ODbL). Compiled and published by The Daily Energy.

Special projects